A coaxial cable loses part of the signal on its way. How much depends on three things: the cable, the frequency and the length. Thicker cable loses less, higher frequencies lose more, and every metre adds to the loss.
Three classes by diameter
Our cables fall into three classes. Thin cable is flexible and easy to route; thick cable keeps the most signal over long runs but needs more room to bend.
Thin & flexible
Under 7 mm · short jumpers, routers, indoor
Low-loss, medium
7–9 mm · antennas and repeaters up to ~30 m
Thick, lowest loss
10 mm and up · rooftop runs up to 100 m
A rule of thumb for loss
- Under 3 dB — negligible: more than half of the signal arrives.
- 3–6 dB — noticeable: a quarter to a half of the signal arrives.
- Over 6 dB — consider a thicker cable or a shorter run.
The configurator shows the expected loss of your exact cable on every common band, from 800 MHz LTE to 5.8 GHz Wi-Fi, and suggests a thicker cable when the loss gets high.
All cables side by side
| Cable | Class | Diameter | Conductor · jacket | 900 MHz | 2600 MHz | Max length |
|---|---|---|---|---|---|---|
| RG58 | Thin & flexible | Ø 4.95 mm | Cu · PVC | 31.3 | 56.4 | 30 m |
| LMR240 | Thin & flexible | Ø 6.1 mm | Cu · PVC | 22.9 | 41.8 | 50 m |
| LMR240 Twin | Thin & flexible | Ø 2 × 6.1 mm | Cu · PVC | 24.8 | 43.3 | 20 m |
| 5D-FB | Low-loss, medium | Ø 7.5 mm | Cu · LSZH | 19.0 | 34.3 | 50 m |
| LMR300 | Low-loss, medium | Ø 7.5 mm | Cu · LSZH | 19.0 | 34.3 | 50 m |
| LMR400 UF Flexible | Thick, lowest loss | Ø 10.29 mm | Cu · PVC | 13.2 | 23.8 | 100 m |
| RG213U | Thick, lowest loss | Ø 10.3 mm | Cu · PVC | 21.7 | 44.0 | 100 m |
| RG214U | Thick, lowest loss | Ø 10.8 mm | AgCu · PVC | 22.7 | 46.0 | 100 m |
| 8D-FB | Thick, lowest loss | Ø 11.1 mm | CCA · LSZH | 14.5 | 28.3 | 100 m |
| 10D-FB | Thick, lowest loss | Ø 13.0 mm | CCA · LSZH | 11.0 | 20.2 | 100 m |
Ready to build your cable?
Any cable, any two connectors, any length from 10 cm to 100 m — assembled and tested in 1–2 days.